A 37-cm-diameter centrifugal pump, running at 2140 rev/min with water at 20°C produces the following performance data:
|
Q, m3/s: |
0.0 |
0.05 |
0.10 |
0.15 |
0.20 |
0.25 |
0.30 |
|
H, m: |
105 |
104 |
102 |
100 |
95 |
85 |
67 |
|
P, kW: |
100 |
115 |
135 |
171 |
202 |
228 |
249 |
|
η |
0% |
44% |
74% |
86% |
92% |
91% |
79% |
(a) Determine the best efficiency point. (b) Plot CHversus CQ. (c) If we desire to use this same pump family to deliver 7000 gal/min of kerosene at 20°C at an input power of 400 kW, what pump speed (in rev/min) and impeller size (in cm) are needed? What head will be developed?
-----------