The following duties are to be performed by rotodynamic pumps driven by electric synchronous motors, speed 100π/n rad ·s−1 (= 50/n rev/s), where n is an integer: (a) 14 m3 ·s−1 of water against 1.5 m head; (b) oil (relative density 0.80) at 11.3 L ·s−1 against 70 kPa pressure; (c) water at 5.25 L ·s−1against 5.5 MPa. Designs of pumps are available with specific speeds of 0.20, 0.60, 1.20, 2.83, 4.0 rad. Which design and speed should be used for each duty?
-----------