Category > Applied SciencesPosted 27 May 2017My Price5.00
The steam has a mass flow rate of approximately 0.2 kg
The steam has a mass flow rate of approximately 0.2 kg/s in a 7.5 cm diameter (ID) pipe with a pressure of 198.53 kPa. Determine the density of the manometer fluid to be used so that pressure differences can be detected accurately and reasonably. A manometer of less than 1 m in height can be considered reasonable. Given Data: Orifice coefficient = 0.61, orifice diameter D0 of 6 cm and Since the manometer fluid height (zm) must be less than 1 m, a value of 0.1 m will be assumed.